> Source: https://docs.cyberelements.io/saas/sl/Usage/Administration/AdminConsole/MainWorkPanel/SitesAndGateways/Html5Gateways/

# HTML5 gateways management

An **HTML5 Gateway** serves the accesses that take place entirely in the browser: the HTML5 (RDP), HTML5 (SSH) and HTML5 (VNC) applications. The Mediation Controller publishes it under a path of its own, and it exchanges with the platform over HTTP or WebSocket.

Like an [Edge Gateway](https://docs.cyberelements.io/saas/sl/Usage/Administration/AdminConsole/MainWorkPanel/SitesAndGateways/Gateways/), it only serves once attached to a [site](https://docs.cyberelements.io/saas/sl/Usage/Administration/AdminConsole/MainWorkPanel/SitesAndGateways/Sites/), and that attachment is done from Sites management.

![](https://docs.cyberelements.io/saas/img/cyberelements/CYE_AdminConsole_Html5Gateways_Module.png)

## Relationship with the Edge Gateway

An HTML5 Gateway **does not replace** an Edge Gateway: it comes in addition to one.

An HTML5 application calls on **both** at launch: an Edge Gateway of the site, which reaches the target machine, and an HTML5 Gateway of the same site, which renders the session in the browser.

> **Where the HTML5 Gateway is placed**
>
> The HTML5 Gateway **does not need to be placed in the resources network**: it never reaches the target machine itself, the Edge Gateway of the site does. Only the Edge Gateway needs to reach the resources.

> **Site with no active HTML5 Gateway**
>
> A site with no active HTML5 Gateway serves no HTML5 application. It may be available for everything else: its HTML5 applications are simply not offered to the user. The portal does not explain their disappearance, and the administration console does not tell an available site from a site available "except for HTML5".

An HTML5 Gateway does not record anything either: its form carries neither a recording certificate nor an archive path. Recording a session, when it is requested, is handled by the Edge Gateway.

## URL and protocol

The URL is mandatory. It is not a full address but the **path** under which the Mediation Controller publishes the HTML5 Gateway, that is, the element that follows the `/` of the address (for example `HTML5-PARIS-01`). That path is declared by CyberElements in the configuration of the Mediation Controller. The console neither derives it nor checks it: the value entered must be the one declared on the platform.

The exchange protocol is either **HTTP** or **WebSocket**, and it has to match what the gateway actually exposes.

## Pairing

The mechanism is the Edge Gateway one: a *Create a pairing token* box reveals the section, the gateway certificate is uploaded, and the resulting token is entered at install time. The expected CN of the certificate is `<gateway name>@<organization>`.

As with an Edge Gateway, the token is **consumed** on the first successful connection: the gateway then moves from *awaiting pairing* to *online*, and the **Authentication Token** field stops being displayed.

> **Token settings and certificate**
>
> **Pairing key validity period** and **IP authorized to use the token** stay inactive until a certificate file matching the chosen format has been supplied. A `.pem` picked while the announced format is `pkcs12` therefore leaves them greyed out.

On an already paired gateway, those two fields do not reopen: they can only be changed while it is awaiting pairing.

## HTML5 Gateway deletion

Only the attachment to a site prevents deletion: the gateway must first be switched to *UNUSED* there. Unlike Edge Gateways, no other configuration holds it back.

## Availability

The module only exists if the tenant **allows HTML5 connections**. That setting is held by the tenant, is made by CyberElements, and is **off by default**.

Without it, the *HTML5 Gateways* tab of [Sites management](https://docs.cyberelements.io/saas/sl/Usage/Administration/AdminConsole/MainWorkPanel/SitesAndGateways/Sites/) and the matching column of its list disappear as well.

## Limits

- No passive mode: an HTML5 Gateway is *ACTIVE* or *UNUSED* within a site. Several active gateways share the load, with no backup.
- No session recording.
- The name follows the same rule as an Edge Gateway one: 50 characters at most, unaccented letters, digits, hyphen, dot and underscore.

---

The field-level detail is described in the [module reference](https://docs.cyberelements.io/saas/sl/Usage/AdminConsoleReference/HTML5Gateways/).

The API endpoints that drive this object are described in the [API reference](https://docs.cyberelements.io/saas/sl/API/APIGuide/#get-/publicapi/-org-/html5gateways/).