Pāriet uz saturu

Changes integrated into CyberElements Bastion 4.7

This page lists, by component, the improvements and fixes integrated into CyberElements Bastion since version 4.6. The most notable features are presented in the release note.

Each entry carries the reference of the matching ticket or tickets (IPC-…, IPD-…): quote it to CyberElements support for any question about an improvement or a fix.

Security

  • IPD-36898, IPC-41817, IPC-47224, IPC-51807, IPC-56413 and IPD-56698: TLS configuration of the Mediation Controller web server: TLS 1.2 and TLS 1.3 are accepted by default, SSL, TLS 1.0 and TLS 1.1 remain refused, and the list of cipher suites is aligned with the advanced hardening guide. TLS 1.3 remains enabled when certificate authentication is mandatory: access without a valid certificate is refused with a 403 error.
  • IPC-41824: Each Web VPN virtual host chooses what it publishes: the Gate portal, and the CyberElements Bastion user portal, administration console and system console, which makes it possible, for example, to publish a console only on an internal network interface (see Virtual hosts). On a new installation, the portal of the underlying Gate platform is no longer published; the portal merged with CyberElements Gate requires it to be published.
  • IPC-42799: Strengthened validation of the names entered in direct SSH recording configurations.
  • IPC-47015, IPC-56504 and IPC-58026: Reduced attack surface: after installation, the Edge Gateway recording web server only listens on the local address (127.0.0.1) for ports 80 and 443. The cleanroom-only-gateway package installs an Edge Gateway without the features specific to CyberElements Gate.
  • IPD-50399 and IPD-51669: Stronger protection against the disclosure of internal information (internal IP address, exposed paths).
  • IPC-50845, IPC-51268 and IPC-53346: Installation now asks for the initial password of the su account, which replaces the default password, including for a Standalone installation from the wizard; it is not asked when the su account already exists, as during an upgrade.
  • IPD-51891: Hardened web server configuration: only explicitly published folders are accessible.
  • IPC-52018: The CAPTCHA is now displayed as soon as the domain is selected and is checked before the login and password.
  • IPC-52031: The product version is no longer displayed on the consoles' login page.
  • IPC-52999, IPC-55641 and IPC-56346: An organisation's “admin” account, a non-nominative global administration account, can be disabled; an administrator still cannot lock themselves out, and unlocking from the system console applies to the users of all local domains.
  • IPC-54640: Authentication hardening: the X-Forwarded-For header is no longer taken into account in authentication operations; the IP address restriction of a local account is checked against the connection address received by the Mediation Controller only.
  • IPC-54818: Hardened the list of authentication domains offered before login: it now only exposes the information needed to choose the domain.
  • IPD-55513 and IPD-55514: On a new installation, the Edge Gateway no longer has an rsync service nor forwards its syslog logs to the Mediation Controller; an upgraded Edge Gateway keeps them.
  • IPC-55552: One-time passwords (OTP) are generated by a cryptographically secure random generator.
  • IPC-55653: Hardened access rights on the RDP and SSH session recordings stored on the Edge Gateway: they can no longer be read by other system accounts.
  • IPC-56862 and IPC-57880: Hardened access to the client certificate (PKCS#12 file) and to the certification authority certificate provided to the CyberElements client: downloading them requires an authenticated session.
  • IPC-56965: Stronger validation of the login entered during authentication on an LDAP domain, so that multi-factor authentication applies in every case.
  • IPD-57074, IPD-57075, IPC-57077, IPD-57078, IPC-57079, IPD-57080, IPD-57337 and IPD-57462: Fixed the LastDisco and XMLRPC security vulnerabilities, which were the subject of security communications: validation of the parameters passed to system commands by the vault and by the host and Edge Gateway management services, validation of organisation names at creation, restriction of the HTTP methods and addresses accepted by the Mediation Controller, review of the disconnection permissions, and blocking of XML-RPC requests on every path exposed by the web server.
  • IPC-57900: Added session recording encryption: the organisation's “Encrypt video recordings” option, disabled by default, encrypts new RDP (with or without agent), Web, Isolate (Web) and SSH recordings stored on the Edge Gateway, which can then only be viewed from the administration console. Recordings made before the option is enabled remain unencrypted.

Mediation Controller components

  • IPC-43840: The Apache error log of the Mediation Controller no longer records errors when the administration console is refreshed.
  • IPC-48425: Workflow diagnostic logs (periodic check, user groups, detected access profiles) can be enabled per organisation in the djangosettings.ini file; they are written under /var/lib/ipdiva/care/logs.
  • IPD-51121: Fixed a typo in an English message of the ipdiva-base package during installation.
  • IPD-51276, IPD-53053 and IPD-53652: Cluster reliability: failover to the secondary node occurs when the application service of the primary node stops responding, the firewall rule set during failover is removed when the node comes back, and changing the cluster addresses no longer resets the addresses and ports of the Web interfaces.
  • IPC-51363: In a cluster, the cleanroom-xmlrpc-api service is now restarted on both Mediation Controllers after an organisation is created or the mode is changed, not only on the local server.
  • IPD-51389, IPD-51390, IPD-51415 and IPD-53078: Expired Web sessions of the Mediation Controller are purged daily, are no longer included in backups and take up less space in a cluster, which limits database growth and backup size.
  • IPC-51656: The permissions of the agentca.crt and agentca.key files, used by ACM, are now restored after installation or upgrade and whenever a gateway used by ACM is modified.
  • IPC-52517: The email sending service is more reliable in a cluster architecture.
  • IPC-52960, IPC-53020, IPD-53021, IPD-54248, IPD-54263 and IPC-54583: CyberElements Bastion is compatible with Debian 13 (Trixie).
  • IPC-53159: Improved reliability of the daily automatic deletion of old videos, whose diagnostic logs can be enabled per organisation (outdated_videos in djangosettings.ini).
  • IPC-53326: The main database of the Mediation Controller can be reached through one or more Edge Gateways, without a dedicated Gate organisation. These Edge Gateways belong to the cleanroom_infra virtual organisation: their certificate is named <name>@cleanroom_infra, their pairing token is generated on the Mediation Controller by clr_gen_defaultgateway_token.py, and they are paired with the --cleanroom-infra option of the pairing script. They are declared with the gateway key of the [database] section of databasesettings.ini; the tunnel is opened on each connection through one of them that is connected. See Main database through Edge Gateways.
  • IPC-53866, IPC-53921, IPC-56578, IPC-56587, IPC-56588, IPC-57103, IPC-57962 and IPC-57966: New multi-node architecture of the Mediation Controller: an organisation created on the master node is propagated to the other nodes, with its database settings and internal vault; Edge Gateways and HTML5 Gateways pair with it, and client connections succeed whichever node receives them. The system console “Switch mode” screen is no longer offered on a server that has joined the architecture.
  • IPC-54454: File synchronisation failures between the nodes of a cluster, including those of the internal vault, are now logged.
  • IPD-54924, IPD-55447, IPD-56384 and IPD-56387: Mediation Controller services reliability: the XML-RPC API service restarts automatically if it hangs or stops, instead of leaving the Web interfaces in error; it starts even when the host manager is slow to start, and the latter's startup timeout is raised to 5 minutes for low-performance machines.
  • IPC-56446: Improved Mediation Controller load handling: it processes twice as many simultaneous requests and regularly recycles its application processes, which keeps memory use from building up day after day.
  • IPC-57014: Fixed excessive memory use by the hourly cleanup of expired sessions when recording integrity control is enabled on an application with many events.

Edge Gateway components

  • IPD-51042: When the system stops an Edge Gateway instance for lack of memory, the other Edge Gateway and HTML5 Gateway instances are no longer stopped.
  • IPC-51690: By default, the Edge Gateway recording service, to which the recording agent sends in particular its videos and metadata, listens on all the IP addresses of the machine (0.0.0.0, port 8443); the Edge Gateway installation no longer asks for this listening address.
  • IPD-51774 and IPD-55671: The Linux Edge Gateway can reach the Mediation Controller through an HTTP or SOCKS proxy, before and after pairing: the appliance wizard asks for the proxy, and the pairing command uses the one from the environment or the one given by its -x and --noproxy options.
  • IPC-52119: Fixed Edge Gateway pairing when certificate authentication is mandatory on the Mediation Controller.
  • IPC-53105: Installing or upgrading the Edge Gateway recording service no longer stops when the permissions or owner of the recording directories cannot be changed, for example on an external mount point: an error message is displayed and the operation continues.
  • IPC-57044: Edge Gateway startup is no longer blocked when the cleanup of leftover tunnels fails.

Administration console

  • IPC-39499 and IPC-47864: Fixed CSV imports in the administration console when the file was exported from a console in another language: the language of the headers is now detected automatically.
  • IPC-39660: Lists in the administration console and the system console are now sorted consistently: the sort that placed all upper-case letters before lower-case ones is replaced by the database sort or, failing that, by a close alphabetical sort (machines, sites, users, domains, alerts, OTP generators, vaults, gateways…).
  • IPC-43940: Module names in the English administration console now use consistent capitalisation.
  • IPC-44135: In the dual lists of the administration console, the domain drop-down list is aligned with the list it filters and follows window resizing.
  • IPC-44480: The name of an Edge Gateway or an HTML5 Gateway now accepts only letters, digits, hyphens, underscores and dots.
  • IPC-45129: File copy alerts now refuse the characters that are not allowed in Windows file names (? | * < > : ").
  • IPC-46182: Fixed the input check of ACM users, which accepted an empty user name after the domain.
  • IPC-46684, IPC-47530, IPC-50489 and IPC-57995: New “Appearance” module: it sets the administration console theme (blue, white or forest green, blue by default) and brands the user portal with the organisation's identity (green-yellow, deep blue or forest green theme, green-yellow by default; login page logo, background image, applications page logo, in PNG, JPG or JPEG format).
  • IPC-46742: An error message is now displayed when deleting an alert used by a notification profile fails.
  • IPC-48621: The Toolbox now provides the Windows Edge Gateway installer.
  • IPC-48726: Fixed administration console exports for a delegated administrator with restricted access: they can export the lists of every module (including applications, gateways and access contracts), but cannot import them.
  • IPC-48832 and IPC-48918: Helpdesk requests: logs and log cleanup now provide a filter on helpdesk events, and the “Application” tab states that only privileged HTML5 applications (RDP, SSH, VNC) can be used with helpdesk requests.
  • IPC-50834 and IPC-51471: The “Applications” module now provides a filter between standard and privileged applications.
  • IPC-51226: Fixed the deletion of temporary accounts of the local domain: an account that reached its end time while the user was not connected remained in the list; it is now deleted when the account list is displayed.
  • IPC-51232: The sender of the SMTP configuration test email can now be changed (“noreply@cleanroom.com” by default, also used when the field is empty), and the error returned by the SMTP server, such as an unauthorised sender, is now displayed in the console.
  • IPC-51344: Fixed the CSV export of applications, which repeated an application as many times as it had keywords.
  • IPC-51798: Fixed authentication of an administrator, or of a local domain user, subject to several IP address restrictions (addresses or subnets).
  • IPC-51972: A button now copies the pairing token of an Edge Gateway or an HTML5 Gateway.
  • IPC-52005: The Workplace association now shows explicit error messages: “Unable to establish connection with Workplace” and “No available gateways”.
  • IPC-52211: Fixed the deletion of an Edge Gateway that remained associated with an LDAP domain configured through a site.
  • IPC-52929: The administration console distinguishes ZTNA (standard applications) and PAM (privileged applications) usage in licence tracking: the “Licenses usage” module shows one curve per licence type and one for the total, and a user running a standard and a privileged application at the same time counts as one licence of each type. On upgrade, licence usage is recalculated for all past sessions: a recorded session counts as PAM, the others as ZTNA.
  • IPC-53031 and IPC-53032: Application and site identifiers are easily available in the administration console, through an “ID” column hidden by default, for example to generate Remote Desktop Manager commands.
  • IPC-53382: Fixed duplicate emails sent by a notification profile when an access request covers several applications; each email now lists only the applications covered by its profile.
  • IPC-53692: Fixed the name display in the user list summary.
  • IPC-54702: The email invitation of a support profile now includes the connection port of the web interface.
  • IPC-55113: Backups of the administration and system consoles offer the “Do not include sensitive data (passwords, password vault content)” option: the archive, meant for troubleshooting by support, contains neither the vaults, nor the organisation encryption key, nor passwords (LDAP, SMTP…), and its restoration is refused.
  • IPC-55210: Fixed the sending of emails to LDAP helpdesk groups when a user requests assistance, including for nested groups and accounts whose CN differs from the login (Active Directory).
  • IPC-55542: Dynamic aliases accept two new variables, %UPN_PREFIX% and %UPN_SUFFIX%, which take the part of the login before and after the “@” (without “@”: the whole login and an empty string); the %USER% variable is unchanged.
  • IPC-55638: When a site is deleted, the list of items that use it is now complete: Workplace association, SSH and agentless RDP recording contracts, virtual machines, OTP, vault and password policies are added to access contracts, domains and notification profiles. The message above the list has been reworded.
  • IPC-55642, IPC-57581 and IPC-57793: The consoles' built-in help now opens the public online documentation; the help embedded in the product has been removed. The Toolbox documentation link also opens the online documentation; its address, like that of the consoles' help, can be overridden by the online_doc property of the djangosettings.ini file (by default, https://docs.cyberelements.io).
  • IPC-57483: In Firefox, the “Browse” button of the certificate authorities field of the console merging with Workplace is displayed at its normal size again.
  • IPC-57563: Import now recognises the column headers of an exported file even when a spreadsheet tool has removed their trailing spaces.
  • IPC-57852: Fixed the error messages displayed when deleting an HTML5 Gateway, which were not translated.

Supervision

  • IPC-53199: New “Active connections” screen, which lists the connections open on the platform (user portal, client, administration console, API, recorded direct access), allows them to be closed and shows licence consumption over time.

Users

  • IPC-51623: In a user's record, the “Applications” tab now offers a search by name and filters by application type (privileged or standard), service type and restriction.
  • IPC-57035: The “Telephone” field of a local user accepts phone numbers in international format, with the country code.
  • IPC-58302: Fixed the user list, which could display the users and groups of another domain when the domain was changed before the list had finished loading.

Authentication domains

  • IPC-42146: The setting that automatically disconnects the oldest session is now available for LDAP and SAML domains, and works again for local domains.
  • IPC-42538: In authentication domains, two administrator groups can no longer have the same name differing only by case; existing duplicates are left unchanged on upgrade.
  • IPC-43099: A button now copies the code during the synchronisation of an Azure domain.
  • IPC-43493: An administrator group that does not exist in the directory can no longer be added to an LDAP domain, as for local domains.
  • IPC-51392: The idle timeout of the tunnel used by connections to LDAP directories increases from 10 to 30 seconds, for directories that are slow to respond.
  • IPC-51423: LDAP domains without a site: the password change options are now shown as soon as an LDAPS server is configured, including with a single server and when an existing domain is opened.
  • IPC-51465: LDAP domains using SASL Digest-MD5 authentication: the password change form is no longer offered after a wrong password. On an LDAPS server, simple authentication is now always used; over LDAP, when the directory requires a password change, the password is additionally checked through the SMB protocol if the “Check if the user needs to change the password” option is enabled in the domain settings, which requires SMB to be allowed between the Edge Gateway and the directory.
  • IPD-51608: Fixed the encoding of the domain read account password, which could make the password change of an Active Directory user fail.
  • IPC-51723: Fixed changing the LDAP administrator group when the domain has several groups.
  • IPC-51752: Changing an Active Directory account password from the user portal: the warning in the LDAP domain configuration now states that a full DN used as the read access account may prevent this change; the account is then entered in the login@domain form.
  • IPC-51855: LDAP search references (searchResRef) are now handled when retrieving users' DN.
  • IPC-52136: Fixed an error message sometimes displayed when deleting an authentication domain.
  • IPC-52224 and IPC-57929: A user deleted from the local domain is now removed from the list of locked users. Accounts deleted before the upgrade remain in that list.
  • IPD-52353: Certificate authentication applies the option that normalises the login to lowercase.
  • IPC-52360: An authentication domain can no longer be renamed with the name of an existing domain, for example “local”.
  • IPC-52367: Fixed detection of Active Directory password expiration when an expiration policy is enabled.
  • IPC-52582: Fixed the LDAP “change password at next logon” requirement with serial authentication domains.
  • IPC-52682 and IPC-55355: Improved performance of serial authentication on local domains.
  • IPC-53201: User attributes read at authentication are cached for evaluating user rules, which speeds up authentication.
  • IPC-53618: Fixed the password change at first login, which was no longer required from a local domain user edited after creation.
  • IPC-54331 and IPC-55236: LDAP searches no longer follow referrals returned by the directory, and only result entries are taken into account when searching for groups.
  • IPC-54554, IPC-54884 and IPC-55455: More reliable account lockout: it no longer depends on the case of the login and takes serial authentication into account, which removes unjustified lockouts observed after upgrading to 4.6. An account locked during serial authentication is now locked for serial authentication rather than in the first domain of the list: it can be viewed and managed among locked users by selecting “Serial authentication”, and its automatic unlocking is set separately in the general options.
  • IPC-54672: The authentication domain list no longer shows the number-of-groups column by default, and the number is only computed when the column is displayed: the list loads much faster with large directories.
  • IPC-54894: Fixed the “Name” column of the user list of a local domain, which remained empty even when a full name was set.
  • IPC-55372 and IPC-55420: User names are no longer case-sensitive, whatever the domain type, local directory included, including for workflows, security keys, locked and temporary users, delegated administrators and serial authentication.
  • IPC-55444: Fixed user accounts being locked: the number of failed authentications was not reset after a successful login, which locked the account at the next failure.
  • IPC-56694: Support for OAuth access token renewal with e-CPS authentication: a user is no longer disconnected from the portal, with their applications closed, a few minutes after signing in.
  • IPC-57183: LDAP requests no longer load the full directory schema: less data is exchanged, which reduces LDAP operations interrupted before completion.
  • IPC-58295: Fixed the escaping of special characters in LDAP search filters.

Control center

  • IPC-43129: Fixed the event counter of live sessions, which was not updated, and an error that prevented access to the section where it is shown.
  • IPC-58445: Fixed the expired-session cleanup task, which could delete Web sessions and their video recordings overnight.

Access conditions

  • IPC-44563: The “Connection address” rule now only accepts letters, digits, “-”, “.” and the regular expression characters ^ + * ? $ ( ) [ ] { } | \ in the domain field.
  • IPC-48988: The “System” access condition rule now refuses empty items or items made only of spaces (files, running processes).
  • IPC-51284: Two access conditions, or two OTP generators, can no longer have the same name, including with leading or trailing spaces.
  • IPC-51300: In the “Certificate” rule, the “User profile field” field is renamed “User attribute” and has a tooltip.
  • IPD-52026, IPD-52065, IPC-52516 and IPC-52631: The “Windows Security Center” compliance rule is available again in the access conditions; for the state of automatic updates, it also checks that the Windows Update service is enabled.
  • IPD-52288: Fixed the nesting of meta-rules: a meta-rule that contains another one was no longer evaluated and invalidated the access.
  • IPC-52658 and IPC-54183: Improved performance of the access contract list, which is no longer refreshed twice when the form is validated.
  • IPC-52694: Compliance rules are included in the CSV export of access contracts.
  • IPC-52697, IPC-52699, IPC-53483 and IPC-57084: Continuous compliance check: the “Keep checking access conditions after authentication” option (“General settings” window of access conditions, disabled by default) checks compliance rules throughout the session, at the chosen “Access conditions checking period (sec.)” (60 seconds by default). When a rule becomes invalid, or the device stops reporting its checks, new applications can no longer be launched and open privileged applications are closed, when they can be closed from the Control center. The “Close the session if a validated condition becomes invalid” option also disconnects the user from the portal. The periodic check also applies to rules that do not depend on device checking, such as date or IP address rules.
  • IPC-53623: Access contracts, as well as agentless RDP and SSH recording contracts, can be disabled: a disabled contract is ignored, its users can no longer access its applications, and the SSH or agentless RDP direct access it covers is refused.
  • IPC-54000: Fixed the handling of Windows Server 2003 in the operating system rule.
  • IPD-54352: Fixed date rules whose start time is midnight, and time ranges that span midnight (for example from 10 p.m. to 6 a.m.).
  • IPC-55488: Fixed access conditions based on an end date, which did not prevent connection to an application after that date.
  • IPC-56506: When the console is associated with Virtual Desktop Workplace, an access contract that would give the same group access to both Workplace applications is rejected on validation.
  • IPD-56979, IPD-56980, IPD-56981, IPD-56982, IPD-57667 and IPC-57792: Added the “Windows Update” device compliance rule, which checks that the Windows device receives updates through three maximum times, in days and hours: since the last successful refresh of the update list (1 day by default, at least one hour), update waiting to be installed (14 days by default) and waiting for a restart (7 days by default); a zero time for the last two tolerates none. The rule also checks, by default, that the automatic update service is enabled.

Workflow

  • IPC-50487: An email can be sent to the user when the approver accepts or rejects their request to access an application; sending is enabled in the general options.
  • IPC-51149: Fixed the time restrictions of workflows when the allowed range spans midnight (for example from 20:00 to 16:00).
  • IPC-52274: Approval of application access requests can be assigned to specific delegated administrator groups, in the new “Workflows” tab of an application (“No delegated administrator”, “All delegated administrators” or “Specify advanced permissions...”). A new application is managed by no delegated administrator; on upgrade, existing applications remain open to all delegated administrators. Delegated administrator groups can also be configured on the default local domain.
  • IPC-52309: Fixed the display of applications to approve for a delegated administrator when validating a workflow request.
  • IPC-52850: Fixed loading of the workflow list while a workflow is being created.
  • IPC-53473: The comment entered by the user in a workflow request is visible in the administration console.
  • IPC-54723: Fixed the conversion of workflows created in 4.5, which blocked access to the workflow menus after the upgrade.
  • IPC-56526 and IPC-57177: Added a “History” tab to the Workflow module: each access request carries a stable identifier, which makes it possible to trace the request, its acceptance or refusal, and its deletion. The history can be filtered, exported in CSV format and read through the API, and the identifier is included in notification emails. The history can be purged immediately or on a schedule.
  • IPC-56784: An administrator can create an approval workflow from the administration console, without waiting for a user request. The public API can also create workflows and approve users' access requests.

Vault

  • IPC-37454: Fixed the error displayed when validating a supervised account of the Systancia Access vault.
  • IPC-41593: Vault in integrated mode: when switching to a remote database (PostgreSQL or Microsoft SQL Server), an explicit message reports that the database already exists or does not exist, and the “Transfer existing data in the new database” check box has been removed: data is always transferred.
  • IPC-48929: Keeper vault: a refresh button, at the foot of the tree, reloads the folder list.
  • IPC-50486: Fixed sign-in to the user portal, which failed for every authentication domain when the Keeper account used for the application token was locked; applications using Keeper aliases remain unavailable while that account is locked.
  • IPC-51818: An application that still uses a dynamic alias now stays in fixed SSO when its last alias is deleted.
  • IPC-51882 and IPC-52063: LDAP password rotation: fixed the detection of eligible domains, and rotation details now include LDAPS attempts.
  • IPC-52141: Fixed the deletion of an application associated with a password rotation alias of the Systancia Access vault.
  • IPC-52216: Fixed the display of the vault alias creation window when it is resized, in both the user vault and the shared vault.
  • IPC-52696: Fixed creating, through the public API, an application with fixed SSO using a Keeper alias not yet known to the product.
  • IPC-53228 and IPC-53717: Fixed case handling when resolving dynamic aliases and retrieving personal alias passwords for non-local domains.
  • IPC-53394: Fixed an issue that could cause the credentials stored in an LDAP user's personal vault to disappear when they signed in with different letter case. On upgrade, personal vault entries created under different cases of the same login are merged.
  • IPC-53516: The personal vault accepts SSH keys in PuTTY (PPK) version 3 format, already accepted by the vault of the administration console.
  • IPC-53798: Improved reliability of alias password rotation in cluster deployments.
  • IPC-54225: Fixed the option that makes an alias revealable, which could not be disabled for personal aliases.
  • IPC-54491: Vault synchronisation no longer changes the modification date of secrets.
  • IPC-54581 and IPC-54582: The vault supports importing ED25519 SSH keys in OpenSSH format, with or without a passphrase, personal vault included.
  • IPC-54952: Fixed the password rotation triggered at the end of a recorded session, which could run on the secondary node of a cluster and randomly lock Active Directory accounts: it is now performed along with scheduled rotations.
  • IPC-57152: Improved reliability of the vault remote database: the connection uses a tunnel opened on demand through the Edge Gateway, instead of a permanent tunnel, and this tunnel remains available for up to one hour for long operations such as database migration.
  • IPC-57546: Vault: the “Display current password” and “Force password renewal” buttons are greyed out for a delegated administrator who does not have rights on the supervised accounts concerned.
  • IPC-57595: CyberElements Bastion now supports the LockSelf external vault, in addition to Keeper: the passwords and SSH keys (with or without a passphrase) it holds are injected when SSH and RDP sessions are opened, without being stored by the product. On upgrade, the existing Keeper configuration and aliases are carried over automatically.
  • IPC-57654: CyberElements Bastion supports the Bitwarden external vault, in read-only mode: connection with the API key of a service account (US, European or self-hosted server), shared collections shown as a tree, and Login and SSH key items usable for SSO injection.

Logs

  • IPC-46446: Automatic logs can now be scheduled “Every month-end”: they are sent on the last day of each month, in the morning. A “Monthly” sending scheduled on a day missing from the following month goes out on the last day of that month, then resumes on the scheduled day.
  • IPC-52942: Operations performed through the API are again shown with their icon in the logs.
  • IPC-54046: Password rotation errors can be deleted from the log: a “Password rotation failures” filter is added to the logs and log cleanup modules.

MFA

  • IPC-40034 and IPC-54699: Fixed RADIUS OTP authentication in PUSH mode, which failed while the non-PUSH mode worked.
  • IPD-42947, IPD-43410, IPD-52324, IPD-52518 and IPD-53906: Import and management of TOTP keys have been reviewed: a secret key of invalid length is logged, and the QR code is generated correctly for a login containing special characters. A connector sending codes by SMS has been fixed.
  • IPC-46514, IPC-48656 and IPC-51627: The administration console login page now displays the enrolment QR code of a TOTP token (Google Authenticator); fixed its display when the name contains a special character.
  • IPC-51694: The same OTP code can no longer be generated twice for a user.
  • IPC-51848 and IPC-51864: FIDO2 keys: for an LDAP domain user, the key is requested regardless of the case of their login, and a recurring error message has been fixed.
  • IPD-52527: Fixed an error when sending OTP codes.
  • IPC-52581: Fixed the loss, on upgrade, of the attribute used to send OTP codes by email.
  • IPC-52869: TOTP key management has been revised: the key size is chosen among 24, 32, 48 or 64 characters, the import checks that each key is valid (length and characters) and displays a line-by-line report, and a tooltip describes the expected CSV file format. The import window no longer reopens when the page is reloaded, which blocked the console.
  • IPC-53660: Fixed the selection of the email recipient for TOTP authentication.
  • IPC-53735: Fixed the enrolment QR code, which was not displayed when the OTP generator name contained an accented character.
  • IPC-54245: Fixed the loss of TOTP secret keys when upgrading from version 4.5.
  • IPC-54351: Fixed FIDO2 key enrolment, which failed for some users.
  • IPC-54416: During TOTP enrolment, in the user portal as well as when signing in to the administration console, the secret key is displayed in clear text below the QR code, for authenticator apps that cannot read QR codes.
  • IPD-56265: Fixed resending the TOTP key by email when the user requests it again.
  • IPC-57557: neomia Pulse multi-factor authentication (keystroke dynamics) supports the new generation of the service: enrolment and verification take place in the authentication window, on the user portal as on the administration console, instead of a redirection to a neomia page. It is used by default; the previous generation remains available as a fallback through the version key of the [pulse] section of the djangosettings.ini file (v2 by default, v1 for the previous generation, which requires the authentication API URL to be filled in the domain). Users already enrolled do not need to enrol again.

System console

  • IPC-49302: Fixed the organisation edit window in the system console, which could be truncated depending on the licence.
  • IPC-49308: A virtual host can use a Web certificate and a type of authentication different from those of the web interface (“Use a different Web certificate from the web interface” and “Use a different type of authentication from the web interface” options): certificate authentication in “Mandatory” mode can thus be restricted to one virtual host, with its own certification authorities. These settings are also available through the virtual host management API.
  • IPC-51290: The “Migrate databases from earlier versions (PostgreSQL only)” option of the system console backup is now always shown, even when an organisation uses an MSSQL database.
  • IPC-51830: A certificate in PEM format can now be added to a PKI of the system console.
  • IPC-54898: System console logging options: when the port of the remote syslog server is not specified, the default port depends on the protocol (514 for UDP, 1468 for TCP, 6514 for TLS) instead of always being 514.
  • IPC-55589: The system backup now deletes the temporary file containing the default database once the archive has been created.
  • IPD-57405: Certificate revocation lists (CRLs) of a PKI configured by URL are downloaded again at the configured interval.

SAML

  • IPC-50405, IPC-50473, IPC-50933, IPC-52140, IPC-52142, IPC-52144, IPC-52901, IPC-52902, IPC-52903, IPC-52906 and IPC-54008: SAML authentication is configured entirely from the administration console: several identity providers can be configured, each in its own SAML domain, a single virtual host is enough whatever the types of domains offered, and the record of a SAML domain user created by the administrator is updated at each authentication (email address and groups, which can then no longer be edited in the console). When a virtual host is created in the system console, the “Enable SAML module” option is checked by default; the SAML domain form displays a warning when no virtual host has the SAML module enabled. The name format (NameFormat) of SAML attributes can be set in the SAML domain: uri (default), basic or unspecified; metadata download works even when an ACL is defined on the default application.
  • IPC-56705: A SAML domain accepts an optional “IDP logout URL”: at logout, the user is also logged out from the identity provider when Single Logout (SLO) is disabled.

Applications

  • IPC-48877: Adding an embedded Edge Gateway whose name is already in use is now refused regardless of case.
  • IPC-51243: The help and error message of standard Citrix StoreFront applications now state that “*” can replace the IP address, the domain or the port.
  • IPC-51244: Fixed a label left in French in the standard NetBIOS application form of the English console.
  • IPC-51618: Import of standard and privileged RDP applications: Boolean options missing from the imported file take their default value.
  • IPC-52565 and IPC-54486: The message displayed when connecting to privileged RDP applications without agent and privileged VNC applications, like the custom message of an application, can close by itself after a delay set on the Edge Gateway (MessageTimeout_Sec parameter of xrdprecord.ini); by default, it stays displayed until the user acknowledges it. This setting avoids a lock-up when the message cannot be acknowledged, for example on a workstation with many screens or with a screen whose resolution exceeds 1920 × 1080.
  • IPD-53674: The WebDAV server of (standard) NetBIOS applications now honours file lock timeouts (the one requested by the application, 10 minutes if none, 12 hours at most): a lock left in place, which prevented some files from being saved, is released when it expires.
  • IPC-53724: Fixed the selection of the Edge Gateway used to create the tunnel of RDP (standard and privileged) and SSH (standard and privileged) applications.
  • IPD-54939 and IPD-54986: Standard SMB file sharing applications support SMB shares that require data encryption, including with an SMB 3 protocol version earlier than 3.1.1.
  • IPC-55524, IPC-55525, IPC-55526, IPC-55529, IPC-55531 and IPC-56140: New privileged “MCP redirect” application type: exchanges between AI agents and MCP (Model Context Protocol) servers go through CyberElements Bastion, which authenticates the connections and traces MCP tool, prompt and resource calls in the control center. This type is a product option, independent of the licence.
  • IPC-55819 and IPC-56957: More reliable access to privileged access workstations (PAW) published through an embedded Edge Gateway. Fixed editing an application published through an embedded Edge Gateway when the gateway itself is not changed.

HTML5 applications

  • IPC-39710: The default port proposed when adding an HTML5 gateway in the association with Workplace changes from 18443 to 8443.
  • IPC-49347: The launch directory option is no longer offered for standard RDP HTML5 applications, which do not support it, as for privileged HTML5 applications with agent.
  • IPC-50407: The clipboard of standard and privileged HTML5 applications can now be used with the Ctrl+C and Ctrl+V shortcuts or the context menu, without going through the clipboard window, when the Chromium-based browser is allowed to access the clipboard (Firefox does not allow it).
  • IPC-51288: Standard HTML5 applications (RDP, SSH and VNC) can now be duplicated.
  • IPC-52358 and IPD-52428: Improved performance of file downloads from privileged HTML5 RDP sessions, with or without agent: the file is downloaded directly by the browser, in a stream separate from the display, which stays fluid during the transfer. Depending on the browser, the user may have to confirm the download.
  • IPC-52670: Standard and privileged HTML5 (RDP) applications offer the “Spanish (Spain)” and “Spanish (Latin America)” keyboards.
  • IPC-53019: The HTML5 components are upgraded to Apache Guacamole 1.6.0 and use FreeRDP 3.
  • IPC-53304: Fixed user session keep-alive with standard and privileged HTML5 applications.
  • IPD-53529: When the HTML5 printer is enabled, it is the default printer of HTML5 (RDP) sessions.
  • IPC-53800: Fixed keys that remained considered as pressed in HTML5 applications (RDP with or without agent, SSH) when the browser window lost focus during the key press: all keys are now released when focus is lost.
  • IPC-53826: Fixed copying from a privileged HTML5 RDP application with agent to the user's workstation, which removed spaces (indentation lost).
  • IPC-54102: Fixed the file transfer drive being disconnected when uploading a large file into an agentless privileged HTML5 RDP session.
  • IPC-54258 and IPC-54269: Standard and privileged HTML5 applications support the trackpad and external keyboard on iPad.
  • IPC-54681 and IPC-55403: The user chooses how HTML5 applications open, in a new tab or in the current browser tab, with the “HTML5 application opening mode” setting of the “Options” window of the user portal (gear button).
  • IPD-54747, IPD-54976, IPD-55549 and IPD-56789: Fixed the “console” option of RDP applications in HTML5, RDP connections in HTML5 with a login in domain\user format and password entry for SSH applications in HTML5. The connection to the HTML5 Gateway is now closed when the browser tab is closed.
  • IPC-55160: Fixed the loss of control of an HTML5 application after pressing Alt+Tab.
  • IPC-55234: Fixed doubled carriage returns when copying and pasting in a standard or privileged HTML5 RDP application.
  • IPC-57479: Fixed privileged HTML5 (RDP) sessions launched without an agent being disconnected because the recorder timeout was wrongly applied to them.
  • IPC-57752: Fixed Ctrl+Alt keyboard shortcuts and flickering of held keys in standard and privileged HTML5 RDP applications.

RDP application

  • IPC-51626: The port of a standard RDS application is now taken into account in the command line.
  • IPC-53014: The expected format for entering several IP addresses in the allowed networks of standard and privileged RDS applications is specified and validated: addresses are separated by “;” or “,”, with or without spaces.
  • IPC-53097, IPC-53370, IPC-53450 and IPC-54035: The network type of agentless privileged RDP applications (RDS and HTML5 (RDP)) can be forced; automatic detection is the default and the available types match those of the Microsoft Remote Desktop client.
  • IPC-53148, IPC-53314 and IPC-53317: An option of privileged RDP (with or without agent) and VNC applications, “Keep session active if the RDP client is minimized”, keeps the session alive when the user minimises the Remote Desktop client window; without it, the session could expire for lack of activity. The option is disabled by default.
  • IPC-53733: Fixed an unexpected xrdp shutdown on macOS or Linux when the keep-session-active option of privileged applications is enabled.
  • IPC-53748: The Num Lock and Caps Lock states are synchronised when agentless privileged RDP applications are launched.
  • IPC-53904: Improved handling of channel opening failures in xrdp.
  • IPC-54115: Fixed launching standard RDS applications when the login or password contains the € character.
  • IPC-54599: Fixed a memory leak in virtual channel redirection of agentless privileged RDP applications.
  • IPC-54817: Fixed the display of a standard or privileged RDP application moved between two screens with different resolutions, with the Windows Remote Desktop client as with the Linux client.
  • IPC-55491: The connection timeout of agentless privileged RDP applications increases from 9 to 30 seconds.
  • IPC-56142: Fixed collisions between standard RDP applications: the plugin suffix they use is now randomly generated.

SSH application

  • IPC-51081: A dynamic alias can now be selected in SSH injection.
  • IPC-51495 and IPC-51993: A single privileged SSH application now provides both terminal connection and SFTP file transfer, including in direct access. The “Enable terminal” option selects SSH access, SFTP access or both, and a third-party client program can be set for SFTP (“Use another client program (SFTP)”); when both accesses are enabled, the user chooses the mode at launch, Cleanroom Desktop included. On upgrade, SSH applications whose file transfer was enabled switch to SFTP only, with their client program: they are used as before.
  • IPC-52394: The “Local Port” field in the advanced settings of standard SSH applications now only accepts values from 0 to 65535.
  • IPC-53056: Fixed an SSH error when a command returns a large amount of data containing non-ASCII characters.
  • IPC-57551: Fixed the recorder of privileged SSH applications sending a request to the Mediation Controller for each null character received.
  • IPC-57874 and IPC-57939: The recorder of privileged SSH applications logs the parameters of each session (host, port, account, authentication method, file transfer and network filtering options) and the details of SSH channel opening failures, which makes troubleshooting easier.

Web and Reverse Proxy applications

  • IPC-44547: The standard and privileged Reverse Proxy application form now validates the characters entered in the virtual host and URL: the URL path accepts only letters, digits and the characters ; / ? : @ & = + $ - _ . ! ~ * ' ( ) #.
  • IPD-48839, IPD-49598, IPC-51253, IPD-51349, IPD-51383, IPD-51632, IPD-51634, IPD-51671, IPD-51945, IPD-51965, IPD-52056, IPD-52073, IPD-52100, IPD-52101, IPD-52143, IPD-52184, IPD-52252, IPD-52377, IPD-52392, IPD-52399, IPD-52407, IPD-52411, IPD-52429, IPD-52583, IPD-52805, IPD-52871, IPD-53095, IPD-53329, IPD-53355, IPD-53471, IPD-53543, IPD-53551, IPD-53683, IPD-53847, IPD-53859, IPD-53887, IPD-53997 and IPD-54092: The rewriting engine of standard and privileged Web applications supports new JavaScript syntaxes and APIs: static and dynamic module imports, import.meta, optional chaining, destructuring, Proxy objects, CSS custom properties, the srcset attribute, XMLHttpRequest.responseURL and the Upgrade-Insecure-Requests mechanism. Many rewriting cases have been fixed (relative URLs, HTML attributes and event handlers, document.write, document.domain, the Origin header in a cross-origin context, fetch() requests, blob: URLs, cookies without a value, stream decompression, XSLT stylesheets, CSP meta tags), and rewriting errors are better traced in the Edge Gateway logs.
  • IPD-50711, IPD-51451, IPD-51470, IPD-51491, IPD-51574, IPD-51584, IPD-51661, IPD-51967, IPD-52677, IPC-52848, IPD-53247 and IPC-53553: CyberElements SSO Configurator has been made more reliable: clicking the login button, clearing injected fields, CSRF tokens, URL changes without navigation, page display when the extension starts, and compatibility with some administration interfaces (firewall, hypervisor, database).
  • IPD-51810: Fixed optional mutual authentication on the entry point for Web access: POST requests could fail randomly (error 413).
  • IPD-52092 and IPD-52854: The local storage (localStorage and sessionStorage) of standard and privileged Web applications is isolated per published site (protocol, host name and port) instead of being shared between them; with the new cookie store of the Edge Gateway, HttpOnly cookies of the Web servers are kept by the Edge Gateway.
  • IPC-52453, IPC-53345 and IPC-53354: Two options of privileged Web and Reverse Proxy applications, “Ignore custom style properties when recording” and “Ignore SVG elements when recording”, disabled by default, exclude these elements from the video: capturing them can slow down the user's browser.
  • IPC-52814: The “Fixed” SSO mode of standard and privileged Web and Reverse Proxy applications no longer adds the user's domain to the login when the alias used has no domain.
  • IPD-52840, IPD-52841 and IPD-52844: CyberElements SSO Configurator supports drop-down lists: a value can be selected automatically when credentials are injected.
  • IPD-53081: Fixed an & character being appended to some POST requests with HTTP NTLM authentication.
  • IPD-53191: Fixed Web applications whose server requests a TLS renegotiation after the request: the page did not load and the session ended in an error.
  • IPC-53260: Improved performance of standard Web and reverse proxy applications.
  • IPC-53313 and IPC-54136: Credential injection by the SSO injector is no longer replayed when the user logs out of the web application and logs in again: the injection configuration is used only once.
  • IPC-53808: Fixed a file descriptor leak when archiving Web videos, when the archive directory is on a different file system from the recording one (a network share, for example).
  • IPD-53838: Added static rewrites for the reverse proxy: search-and-replace rules, declared in the Edge Gateway gateway.xml file (static-rewrite-engine), apply to the content of responses whose address matches a pattern; they make it possible to publish in reverse proxy an application that only needs a minor change.
  • IPC-53892: Fixed JavaScript errors caused by session recording on some privileged Web applications, such as HPE Aruba ClearPass.
  • IPC-54187: Fixed the recording mode applied when two Web applications with the same target are opened.
  • IPD-54220: Internal HTTP headers added by the Edge Gateway are removed from requests forwarded to Web servers.
  • IPD-54262, IPD-54340, IPD-54389, IPD-54522, IPD-54615, IPD-55007, IPD-55038, IPD-55076, IPD-55142, IPD-55144, IPD-55214, IPD-55260, IPD-55321, IPD-55934, IPD-56692, IPD-56758, IPD-56966, IPD-56986, IPD-57155, IPD-57618, IPD-57942, IPD-58009 and IPD-58170: The rewriting engine of standard and privileged Web applications supports new elements: SVG files and the use tag, the XMLHttpRequest.getAllResponseHeaders method, reading innerHTML, the Location.reload() parameter, the Function constructor, the caller attribute of functions, Proxy objects and Symbols in Object.assign. Rewriting is more reliable for CDATA and base tags, JavaScript attributes, the style attribute on recent Firefox browsers, optional call chains, expired cookies, 303 responses with malformed headers and applications that redefine window.localStorage; Content-Security-Policy-Report-Only headers are now removed in the same way as Content-Security-Policy headers.
  • IPC-54310, IPC-54412, IPC-54479, IPC-54480, IPC-54624, IPC-54625, IPC-55040, IPC-55173, IPC-55207, IPC-55208, IPC-55517, IPC-55518, IPC-55679, IPC-55714, IPC-55715, IPC-55718, IPC-55755, IPC-55758, IPC-55759, IPC-55782, IPC-56247, IPC-56777, IPC-57042, IPC-57348, IPC-57645, IPC-57818, IPC-58007 and IPC-58242: New Isolate (Web) application type: the web application opens in a browser running in an isolated Docker container, on a container host declared in the administration console, from image templates pulled from a Docker registry; the user's workstation only receives the display. These applications come in a privileged version, whose session can be recorded (visited URLs included), and a standard version; they can be published in remote browser isolation (RBI) mode with URL entry, show or hide the browser bar, inject the user's credentials, and can be imported, exported and managed through the API. The Toolbox provides the isolation engine package. This type is a product option, independent of the licence. For browser-type image templates, removing the container when it stops is enforced. The Edge Gateways used to launch Isolate (Web) applications are chosen in the container host configuration, from the administration console, master Edge Gateways being used first; when this configuration is saved, a warning lists the Edge Gateways whose recording certificate cannot be used as a server certificate, as session recording does not work with them.
  • IPD-54816: Fixed the URL of WebSocket connections without a path, which lacked the trailing slash.
  • IPC-55013: Fixed session recording of privileged Web applications on pages containing tags without a rel attribute.
  • IPD-56168 and IPD-57658: The authenticating reverse proxy ignores X-Forwarded-Host headers received from the client. The x-forwarded-proto key of the gateway.xml file is now taken into account: enabled by default, it keeps the X-Forwarded-Proto header sent to the web server, and disabling it removes the header.
  • IPD-56465: The SSO injection configuration of Web applications accepts a delay parameter, in milliseconds, on each field or button: the injection waits for this delay, useful for an application that is slow to load.
  • IPD-56473 and IPD-57572: More reliable standard and privileged Reverse Proxy applications: fixed an unexpected Edge Gateway stop during an NTLM authentication without target information, and HTTP date handling.
  • IPC-56874: When the user reaches the user portal through the virtual host name of a standard or privileged Reverse Proxy application, that application launches automatically, in the same tab, once the user is authenticated; a standard or privileged Web application launches likewise on the virtual host set in its “Automatic launch on virtual host” field. The path requested on the virtual host is kept.
  • IPD-56888, IPD-56930 and IPD-57370: The Linux Edge Gateway has a new cookie store for Web applications: it keeps the cookies of the Web servers there, and regularly purges those of sessions inactive for 48 hours, which improves reliability under load. It is active by default, upgraded Edge Gateways included; the use-cookiestore element of the gateway.xml file can disable it. Cookies are also isolated per fully qualified domain name.
  • IPC-57135: SSO URL validation for standard and privileged web applications ignores query parameters.
  • IPD-57137: Single sign-on for standard and privileged Web applications now supports HTTP Digest authentication. When the server also offers Basic authentication, Basic remains preferred.
  • IPC-57193: Improved reliability of session recording of privileged Web applications, which could freeze or close the session: on heavy pages, the video is sampled less often (down to one frame per minute).
  • IPD-57589: CyberElements SSO Configurator can also be opened from the page context menu (right-click, or Shift + right-click on pages that block right-click), which makes it usable in a pop-up window.
  • IPC-57616: Credential injection into web forms fires the events expected by pages (text field change, pointer events on button clicks), making SSO more reliable on modern web applications.
  • IPC-57821: Fixed session recording of privileged Web applications on pages that contain frames (iframes) or embed their own JavaScript libraries: the page is no longer reloaded during recording and frames are captured correctly.
  • IPD-58094: Fixed an Edge Gateway memory leak with Web applications.

Virtual desktops

  • IPC-53874, IPC-53875, IPC-53876, IPC-53877, IPC-53880, IPC-53883, IPC-54771, IPC-54964, IPC-55037, IPC-55073, IPC-55366, IPC-55724, IPC-55727, IPC-56063, IPC-57111, IPC-57283, IPC-57393, IPC-57429, IPC-57464, IPC-57466, IPC-57473, IPC-57478, IPC-57486, IPC-57489, IPC-57491, IPC-57496, IPC-57741, IPC-58125 and IPC-58135: New virtual desktop applications, standard and privileged, managed from the administration console without Virtual Desktop Workplace: declaration of virtualisation hosts (VMware, Proxmox VE), virtual machines and their snapshots, creation of clones and management of their maintenance mode, launch from the user portal as a web console or over RDP. A virtual desktop can in particular serve as a jump workstation to reach several VPNs. This type is a product option, independent of the licence. Virtual desktop clones are created in batches, within the maximum number of clones created simultaneously set on the virtualisation host (5 by default); extra clones wait in the “Waiting to be cloned” state. In automatic management, the clone pool is adjusted to the requested number, including by deleting surplus available clones. Standard virtual desktops can be accessed through the Web console or RDP, and the snapshot list of a Proxmox host shows whether snapshots include RAM.
  • IPC-57312: Virtual Desktop Workplace applications can be launched from an external network (WAN) with the Virtual Desktop Workplace client: the association with Workplace opens a tunnel through the Edge Gateway.

VPN and tunnels

  • IPC-46872, IPD-52641 and IPC-58091: Standard VPN applications now support bridge mode: the interface, the address range or a fixed IP address, and the gateway of each route are set for it, including through CSV import/export and the API. Ethernet frames other than IPv4, IPv6 and ARP (for example Spanning Tree protocol frames) received by a VPN application are dropped without filling the Edge Gateway logs; a reminder is logged every 1,000 dropped frames of each type. In bridge mode with all traffic redirected into the VPN tunnel, the default gateway is mandatory, from the administration console as through the public API or CSV import.
  • IPC-49242 and IPC-50828: Standard VPN application form: fields now show input examples, the DNS servers field accepts only IP addresses, and the error message states that a field shown in red is required to add an item to the list below it.
  • IPC-50805: In the standard Generic tunnel application form, the “Launch Executable” option now comes first in its tab.
  • IPC-52155: Fixed the tunnelling launcher failing to unpack when one of its files is in use.
  • IPC-53117: Fixed the standard Generic tunnel application form: advanced settings are hidden again when the last HTTP, HTTPS or Lotus Web redirect is removed.
  • IPC-54386: The " and ‘ characters are now supported in the passwords of port forwarding applications (standard Generic tunnel type).
  • IPD-54540, IPD-54696, IPD-54852, IPD-56268 and IPD-56344: Application tunnels of the Windows client are more reliable: redirected printing in an RDP session works again, interception no longer propagates to processes launched from a remote desktop server, the redirection warning window introduced by a Windows update is no longer displayed when standard RDS applications are launched, and name resolution can be handled within the tunnel.
  • IPC-56354: Added the “Enable hostname redirection for mstsc.exe” option to standard RDS applications and to privileged RDS applications with agent: the Remote Desktop client connects to the server under its host name, which the Windows client routes to the tunnel, instead of a local address. The option is disabled by default.

User portal

  • IPC-38870, IPC-43028, IPC-50926 and IPC-50927: The list view of the user portal now also applies to the Virtual Desktop Workplace applications and desktops (association with Workplace) and to the CyberElements Gate applications shown in the merged portal. Filtering by category and by favourites in the user portal now also applies to the CyberElements Gate applications shown in the merged portal. The user portal search now also finds the CyberElements Gate “Files” applications shown in the merged portal.
  • IPC-40180: Fixed user portal access for an assistant with a pending assistance request, when one of their access contracts has a device compliance rule that denies them access.
  • IPC-48471: The user portal now displays a warning banner, which names the rules that are not met, when applications are hidden because an access contract rule is not met, such as an antivirus rule.
  • IPC-48629: Personal vault: when a personal alias is modified, changing its user name now requires a new password (or a new SSH key for an SSH key alias), as in the administration console; simply renaming the alias does not.
  • IPC-49150: The form page of the user portal driver (launching applications and authenticating from a third-party tool) is now translated into all portal languages.
  • IPC-50833: The direct access tokens button of the user portal now shows its tooltip.
  • IPC-50915: The user portal history now shows the name of the alias involved in each personal vault operation.
  • IPD-51174, IPD-51259, IPD-52206 and IPD-52773: Fixed errors when the user portal is accessed through a reverse proxy, when an application is launched automatically through a virtual host or through its URL, and in the encoding of credentials passed at launch.
  • IPC-51263: Fixed the display of the credentials of a personal alias in the user portal, which was refused for lack of permissions.
  • IPC-51264: Fixed authentication when an organisation is stored in the browser's local storage.
  • IPC-51902: The user portal now shows a loading screen until the list of applications has been loaded.
  • IPC-52370: Faster loading of the application list.
  • IPC-52576: Fixed the handling of restrictions when access contracts are blocked by rules.
  • IPC-52579: Fixed launching a standard or privileged RDS application whose name contains a UTF-16 character from the user portal: the portal's loading window failed and the application did not start.
  • IPC-53871 and IPC-53949: Fixed case handling of the user login at authentication and in session variables.
  • IPC-54205: Fixed the domain name being displayed twice in the user portal after returning to the domain selection page.

Clients

  • IPD-36855 and IPD-56017: The macOS RDP client is now named RDPClient; its “About” window shows its icon and states that it is derived from FreeRDP. The macOS RDP client is signed and notarised by Apple.
  • IPD-39682, IPD-54131, IPD-54164 and IPD-54229: macOS client: FreeRDP has been upgraded to version 3.17.2 with Apple Silicon support (macOS 14 and 15), RDS broker connections no longer depend on Python, and RDP session launch when the login contains @ or \, and local printer mapping have been fixed.
  • IPD-40529: Single sign-on (SSO) for SSH applications now works with the macOS and Linux clients. On Linux, it requires the sshpass package on the workstation; without it, the connection opens without SSO.
  • IPD-51052: Linux client: fixed the version shown in the “About” window on Ubuntu 22.04, and a single installation notice now covers the three supported Ubuntu versions.
  • IPC-51425, IPD-51481 and IPC-51482: The Windows setup programs of the client and the agents no longer use VBScript, whose removal Microsoft has announced.
  • IPC-51667 and IPC-51797: In silent installation of the client with Cleanroom Desktop, an incorrect variable now makes the installation fail, with an error in the Application log, instead of installing Cleanroom Desktop with empty fields.
  • IPC-51668: The Cleanroom Desktop settings window can no longer be validated while a field is in error.
  • IPC-52622: Improved reliability of the Cleanroom Desktop client when a large number of applications (several thousand) must be loaded.
  • IPD-54459, IPD-54481, IPD-54586, IPD-55579, IPD-55752, IPD-55777 and IPD-55787: The macOS RDP client is more reliable in multi-monitor configurations (HiDPI screens, returning to full screen, resizing with smart sizing, moving a resizable window to another screen) and again displays an error message when a connection fails.
  • IPD-54478 and IPD-54798: The macOS RDP client can write its logs to ~/.IPdiva/Plugin/FreeRDP_logs/, enabled through a macOS preference (defaults write com.systancia.ipdiva.macfreerdp LogToFile -bool true, level set with LogLevel), and no longer intercepts keyboard shortcuts specific to its graphics library.
  • IPD-55699: The Windows client now includes OpenVPN 2.7.
  • IPD-56441: Fixed the launch of remote desktop applications from the Linux client on Ubuntu 26.04, which ships FreeRDP 3.
  • IPD-56470: The Windows client supports TLS 1.3, including on Windows 10: it can connect to a Mediation Controller that only accepts TLS 1.3. It still uses the Windows certificate store to validate the server certificate.
  • IPC-56615: Fixed the host name intermittently shown in the application window title.
  • IPC-57253: The CyberElements client can coexist with an OpenVPN (community edition) installation on the same workstation. Its setup program installs only the OpenVPN components the client needs, as before, or the complete OpenVPN (Open_VPN_COMPLETE feature on the command line), in version 2.7.0, which updates an earlier version already present.

Agents

  • IPC-50098 and IPC-57278: The advanced traces of the recording agent are available for privileged RDS and HTML5 (RDP) applications without installing the agent on the target server. In this mode, direct access and network filtering are not available. This mode is reserved for target Windows RDS servers, on which SMB guest access must be enabled.
  • IPC-51419: The Windows recording agent installer no longer installs obsolete Microsoft redistributables.
  • IPC-57277: The Linux filtering agent is available for Debian 13 and Red Hat Enterprise Linux 10, in addition to the versions for Debian 12 and Red Hat Enterprise Linux 9.
  • IPC-57728: Deploying the recording agent from the console, for privileged RDP applications and virtual desktops, now also installs the root certificates of the site's Edge Gateways, which the agent uses to reach the recording service; the Windows certificate stores are not modified, and the agent still accepts the authorities they contain.

Direct access

API

  • IPC-52977 and IPC-57829: Improved the OpenAPI description of the API and its interactive documentation. API defects fixed at the same time change some responses for integration scripts: a duplicate name or the deletion of an object still in use returns code 409, errors previously returned as 500 now return 400, 403, 404 or 502, the type of an application (application_type) can no longer be changed, and updating an organisation with PUT requires allow_html5, allow_acm and safe_max_user. The interactive documentation of the public API is served by the Mediation Controller at https://<Mediation Controller>/publicapi/doc/, without Internet access, and the OpenAPI schema can be downloaded from https://<Mediation Controller>/publicapi/schema/.
  • IPC-53675: API fixes for local users and groups: a group is returned as a key-value object, like in the rest of the API, instead of a positional list, and its creation returns code 201 with the created group; a group description, and a user's email address, phone, full name and validity dates, are no longer mandatory; the email address and the dates of a temporary profile are checked; a missing field returns 400 instead of 500; deleting a user is complete, so that a user with the same name can be created again.
  • IPC-56172, IPC-56459 and IPC-56773: Added public API endpoints to manage authentication domains, their groups and their users, including creating and deleting accounts in a local domain, as well as the order of serial authentication.
  • IPC-56573: The public API handles standard and privileged applications for every application type except virtual desktops: RDP, SSH and VNC (including HTML5), recorded Web and Reverse Proxy, Citrix ICA and Nfuse, NetBIOS share, SMB share and MCP redirection. The application list now includes standard applications, and creating or modifying an application checks the submitted values more thoroughly (application type cannot be changed after creation, consistency of addresses in dynamic mode, server required depending on the type).
  • IPC-56775: New public API endpoints for the built-in vault: reading an alias secret (password or SSH key), when password display is allowed, with logging; forced password rotation and the alias exposure history; configuration of the vault database (local or remote) and of its options. Choosing the vault type remains reserved to the administration console.
  • IPC-56880, IPC-57255, IPC-57256, IPC-57374, IPC-57398 and IPC-57402: Added API key authentication to the API, in addition to the session token: keys are managed from the “API keys” module of the administration and system consoles, have a lifetime of 90 days by default (0 for an unlimited key), and their use can be restricted by IP address. By default, an API key can be used from any address; the restriction accepts addresses, ranges and subnets. The “API keys” module is not offered to delegated administrators, and the key expiry email states the key owner.
  • IPC-57624: Added two public API endpoints: the log, paginated and filterable (period, domain, event type), and the list of security keys registered by users.
  • IPC-57627: Added public API endpoints to list, lock and unlock user accounts, which allows users to be blocked in bulk. The list gives the origin of each lock and its automatic release date; the account calling the API cannot be locked.